UX 100 :

2 GHz - 6 GHz / 100 W CW


  • Class A solid state
  • Broadband (instantaneous single band): 2 GHz – 6 GHz
  • Typical output power : 100 W CW
  • Linear output power guaranteed with harmonics < -20 dBc
  • Air cooling: self contained fans
  • Can operate in full mismatch conditions without damage
  • Upgradable to UX 180 possible (18U)
  • Reliable, efficient and robust
  • 19" Rack
  • 3 years standard warranty
  • Export license can be requested


VERSIONS :

  • UX 100 D amplifier with:
    • Display
    • Digital control
    • IEEE 488 GPIB Communication
  • UX 100 DC : UX 100 D with :
    • Integrated bidirectional coupler
    • display of instantaneous power


MAINTENANCE :

  • Amplifier designed for minimal maintenance
    • Easy access to all parts
    • Modular design
    • Repairs with minimum adjustments
  • Rapid diagnostic
  • Minimal downtime
  • Contract for preventive and corrective maintenance available


APPLICATIONS :

  • EMC tests
  • RF tests and instrumentation
  • Radiocommunication
  • Measurement and research laboratories


Download the datasheet

  • Frequency bandwidth : 2 GHz - 6 GHz
  • Typical output power : 100 W
  • Power at 3 dB compression : 100W min. up to 4GHz / 80W min. from 4GHz to 6GHz
  • Power at 1 dB compression : 75W min. up to 4GHz / 60W min. from 4GHz to 6GHz
  • Harmonics distortion : H2,H3 < -20 dBc for the output power at 1 dB compression
  • Class type : Class A
  • Gain : 52 dB
  • Linear power gain flatness : ± 5 dB max
  • Mismatch tolerance : infinite without damage
  • Input impedance : 50 ohms / VSWR: 2:1max
  • Output impedance : 50 ohms / VSWR: 2:1max
  • Input power : +10 dBm max.
  • RF input connector : Type N fem. (front or rear panel) – other connector type on request
  • RF output connector : Type N fem. (front or rear panel) – other connector type on request
  • Safety interlock : Connector type BNC
  • Digital control : Transistors, power supplies and internal temperature
  • Communication interface : IEEE 488
  • 4 lines digital display : Status, faults, (direct and reverse instantaneous power for DC version)
  • Ambient operating temperature : 0 °C / + 35 °C
  • Room temperature storage : -20 °C / +70 °C
  • Cooling : Forced air: 120 l/sec max. (self contained fans)
  • Power voltage : 90-250 VAC, 47-63 Hz, single phase
  • Rated current : 9.6 A at 110 VAC / 4.6 A at 230 VAC
  • Dimensions : 640 x 450 x 312 mm (7U) / 25.2 x 17.7 x 12.3 in (7U)
  • Weight : 37 kg / 81 lb

UX 100 DC version :
  • Integrated bidirectional power coupler : Coupling factor 54 dB typ.
  • Power coupling connector : Type N fem. (front or rear panel)
  • Estimated output power losses due to the coupler : 0.5 dB


Download the datasheet
  • External coupler
  • RF Power cable
  • Switching unit

 

 

 

 